Water system

| Model | 04E(3)V3 | 06E(3)V3 | 08E(3)V3 |
|---|---|---|---|
| Heating capacity (KW) | 4.30 (1) / 4.60 (2) | 6.00 (1) / 5.90 (2) | 7.50 (1) / 7.90 (2) |
| Power input Heating (kW) | 0.84 (1) / 1.26 (2) | 1.24 (1) / 1.69 (2) | 1.63 (1) / 2.23 (2) |
| COP | 5.10 (1) / 3.65 (2) | 4.85 (1) / 3.50 (2) | 4.60 (1) / 3.50 (2) |
| Space heating Average climate water SCOP | 3.26 | 3.26 | 3.32 |
| Dimensions (HeightxWidthxLength) mm | 770 x 1,250 x 362 | 770 x 1,250 x 362 | 770 x 1,250 x 362 |
| Weight (kg) | EV3: 88, E3V3: 91 | EV3: 88, E3V3: 91 | EV3: 88, E3V3: 91 |
| Operation range Heating Water side | EV3: 9 ~ 65 / E3V3: 15 ~ 65 | EV3: 9 ~ 65 / E3V3: 15 ~ 65 | EV3: 9 ~ 65 / E3V3: 15 ~ 65 |
| Power Supply Hz/V | V3/1~/50/230 | V3/1~/50/230 | V3/1~/50/230 |
| Current Recommended fuses | 20 | 20 | 25 |